Code
0.502.136
Category
Tescom UPS
Rated Voltage
380 / 400 / 415 Vac (L-L)
Voltage range
304~478Vac (L-L), full load 228V~304Vac (L-L), load decrease linearly according to the min phase voltage
Rated frequency
50 / 60 Hz (auto-sensing)
Frequency range
40 ~ 70 Hz
Power factor
> 0.99Total Harmonic Distortion (THDi) <3% (full linear load)
Rated Voltage
380 / 400 / 415 Vac (L-L)
Voltage Regulation
= +- 1% (full linear load)
Frequency
Synchronized with utility in mains mode, 50/60 Hz ±0.1% in battery mode
Waveform
Sinusoidal
Power factor
1
Harmonic Distortion
<1% (full linear load) <3% (full non-linear load according to IEC/EN62040-3)
Current Crest Ratio
3:1
Overload
<110%, 60min, 110%~125%, 10min; 125%~150%,1min, >150%, 200ms
Bypass voltage range
Selectable, default -20%~+15% Up limited: +10%, +15%, +20%, +25%; Down limited: -10%, -15%, -20%, -30%, -40%
Bypass frequency range
Selectable, + - 1Hz, + - 3Hz, + - 5Hz
Bypass overload
125%: long term operation; 125%~130%: 10min; 130%~150%: 1min; 150%~400%: 1s; >400%, less than 200ms
DC voltage
120 ~ 240 Vdc settable
Charging current
10A Max
Recharge time
90% capacity restored in 8 hours
Charger voltage precision
1%
Inbuilt battery
N/A
Efficiency
95% Max
Transfer time
0 ms
Protections
Short-circuit, output overload, overtemperature, battery low voltage, overvoltage / undervoltage and fan failure
Max. number of parallel connections
4
Communications
RS232, USB, RS485, EPO, Dry contacts, Parallel port (Standard) SNMP card, WI-FI card, GPRS card, SMS alarms (Optional)
Display
LED + 5 inches LCD touch screen
Operating temperature
0C ~ 40C
Storage temperature
Min 40 C Under Zero ~ 70 B360C (B360without battery)
Relative humidity
0 ~ 95% (non-condensing)
Altitude
<1000m, load derated 1% per 100m from 1000 ~ 2000m
IP rating
IP 20
Noise level at 1 m
58dB 100% load, 55dB 50% load
Dimensions (mm)
250 x 840 x 930

Is expected
Code
0.502.138
Category
Tescom UPS
Rated Voltage
380 / 400 / 415 Vac (L-L)
Voltage range
304~478Vac (L-L), full load 228V~304Vac (L-L), load decrease linearly according to the min phase voltage
Rated frequency
50 / 60 Hz (auto-sensing)
Frequency range
40 ~ 70 Hz
Power factor
> 0.99Total Harmonic Distortion (THDi) <3% (full linear load)
Rated Voltage
380 / 400 / 415 Vac (L-L)
Voltage Regulation
= +- 1% (full linear load)
Frequency
Synchronized with utility in mains mode, 50/60 Hz ±0.1% in battery mode
Waveform
Sinusoidal
Power factor
1
Harmonic Distortion
<1% (full linear load) <3% (full non-linear load according to IEC/EN62040-3)
Current Crest Ratio
3:1
Overload
<110%, 60min, 110%~125%, 10min; 125%~150%,1min, >150%, 200ms
Bypass voltage range
Selectable, default -20%~+15% Up limited: +10%, +15%, +20%, +25%; Down limited: -10%, -15%, -20%, -30%, -40%
Bypass frequency range
Selectable, + - 1Hz, + - 3Hz, + - 5Hz
Bypass overload
125%: long term operation; 125%~130%: 10min; 130%~150%: 1min; 150%~400%: 1s; >400%, less than 200ms
DC voltage
120 ~ 240 Vdc settable
Charging current
10A Max
Recharge time
90% capacity restored in 8 hours
Charger voltage precision
1%
Inbuilt battery
(20+20) x 9AH, + -240VDC
Efficiency
95% Max
Transfer time
0 ms
Protections
Short-circuit, output overload, overtemperature, battery low voltage, overvoltage / undervoltage and fan failure
Max. number of parallel connections
4
Communications
RS232, USB, RS485, EPO, Dry contacts, Parallel port (Standard) SNMP card, WI-FI card, GPRS card, SMS alarms (Optional)
Display
LED + 5 inches LCD touch screen
Operating temperature
0C ~ 40C
Storage temperature
Min 40 C Under Zero ~ 70 B360C (B360without battery)
Relative humidity
0 ~ 95% (non-condensing)
Altitude
<1000m, load derated 1% per 100m from 1000 ~ 2000m
IP rating
IP 20
Noise level at 1 m
58dB 100% load, 55dB 50% load
Dimensions (mm)
250 x 800 x 700

Is expected
Code
0.502.128
Category
Tescom UPS
Nominal Voltage
3 x 400 VAC (3Ph+N)
Voltage range
110-300 VAC 50% load 176-276 VAC 100% load
Frequency range
46~54 Hz or 56~64Hz
Power factor
>= 0.99 @ 100% load
Output Voltage
208/220/230/240VAC
AC Voltage Regulation
- + 1
Frequency Range
46~54Hz or 56~64Hz
Current Crest Ratio
3:1 (max.)
Harmonic Distortion
<= 2 % THD (Linear Load) <= 5 % THD (Non-linear Load)
Transfer Time
AC mode to Battery mode= Zero, Inverter to Bypass= Zero (when phase lock fails, <4ms interruption occurs from inverter to bypass)
Waveform
Pure Sine wave
Overload
100-110% for 60 min, 110-125% for 10 min, 125%~150% 1min, >150% immediately
AC Mode
95.5%
ECO Mode
98.5%
Battery Mode
94.5%
Battery Type
Depending on the capacity of external batteries
Internal Battery Space
N/A
Charging Current
12A
Charging Voltage
273 VDC + - 1% (Based on 20pcs bateries)
LCD Panel
color LCD
Full Protection
Overload, Over-temperature,Utility abnormal, UPS fault, UPS warning, battery low,etc
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continuously sounding
Standard Model Dimension, (mm)
626x 250 x 827
Net Weight
46.5
Operation Humidity
0-95 % RH 0- 40C (non-condensing)
Noise Level
Less than 65dB 1 Meter
Smart RS-232/USB & Softwarel
Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux and MAC

Is expected
Code
0.502.139
Category
Tescom UPS
Rated Voltage
380 / 400 / 415 Vac (L-L)
Voltage range
304~478Vac (L-L), full load 228V~304Vac (L-L), load decrease linearly according to the min phase voltage
Rated frequency
50 / 60 Hz (auto-sensing)
Frequency range
40 ~ 70 Hz
Power factor
> 0.99Total Harmonic Distortion (THDi) <3% (full linear load)
Rated Voltage
380 / 400 / 415 Vac (L-L)
Voltage Regulation
= +- 1% (full linear load)
Frequency
Synchronized with utility in mains mode, 50/60 Hz ±0.1% in battery mode
Waveform
Sinusoidal
Power factor
1
Harmonic Distortion
<1% (full linear load) <3% (full non-linear load according to IEC/EN62040-3)
Current Crest Ratio
3:1
Overload
<110%, 60min, 110%~125%, 10min; 125%~150%,1min, >150%, 200ms
Bypass voltage range
Selectable, default -20%~+15% Up limited: +10%, +15%, +20%, +25%; Down limited: -10%, -15%, -20%, -30%, -40%
Bypass frequency range
Selectable, + - 1Hz, + - 3Hz, + - 5Hz
Bypass overload
125%: long term operation; 125%~130%: 10min; 130%~150%: 1min; 150%~400%: 1s; >400%, less than 200ms
DC voltage
120 ~ 240 Vdc settable
Charging current
10A Max
Recharge time
90% capacity restored in 8 hours
Charger voltage precision
1%
Inbuilt battery
"(15+15) x 9AHx 2 strings + -180VDC"
Efficiency
95% Max
Transfer time
0 ms
Protections
Short-circuit, output overload, overtemperature, battery low voltage, overvoltage / undervoltage and fan failure
Max. number of parallel connections
4
Communications
RS232, USB, RS485, EPO, Dry contacts, Parallel port (Standard) SNMP card, WI-FI card, GPRS card, SMS alarms (Optional)
Display
LED + 5 inches LCD touch screen
Operating temperature
0C ~ 40C
Storage temperature
Min 40 C Under Zero ~ 70 B360C (B360without battery)
Relative humidity
0 ~ 95% (non-condensing)
Altitude
<1000m, load derated 1% per 100m from 1000 ~ 2000m
IP rating
IP 20
Noise level at 1 m
58dB 100% load, 55dB 50% load
Dimensions (mm)
250 x 840 x 930

Is expected
Code
0.502.133
Category
Tescom UPS
Voltage
100 / 110 / 120 V: 80 - 150 Vac, 220 / 230 / 240 V: 162 - 295 Vac (145 - 295 Vac optional)
Frequency
50 / 60 Hz + - 10% (auto-sensing)
Voltage
100 / 110 / 120 Vac + - 10% or 220 / 230 / 240 Vac + - 10%
Frequency
50 / 60 Hz + - 1% (auto-sensing)
Waveform
Mains mode: pure sine wave Battery mode: simulated sine wave
Transfer time
Typical 2 - 7 ms, 10 ms max.
DC voltage
24 V
Configuration
12 V / 9 Ah x 2
Recharge time
6 - 8 h
USB (optional)
Supports Windows? 98 / 2000 / 2003 / XP / Vista / 2008 / Windows?7 / 8 / 10
Protections
Short circuit - battery overcharge - overdischarge - overload - surge
Humidity
20 - 90% RH @ 0- 40 (non-condensing)
Noise level
<= 40 dB (1 m)
Metal Case
Net / Gross weight (kg) 12.9 / 13.3, Dimensions 25 x 380 x 225, Packaged dimensions: 161 x 369 x 290, Quantity /20ft 1000 pcs

Is expected
Code
0.502.124
Category
Tescom UPS
There are 30 products
Products 1 - 6 of 30
Prices do NOT include VAT
Our Certifications
Why we Stand out
MORE
Microsoft authorized refurbisher
Microsoft surface authorized reseller
ADISA Accredited Pass
BLANCO
WEEE
ISO 27001
ISO 14001
ISO 9001
×

This site uses cookies to distinguish visitors. To accept the use of cookies, please select
Cookies policy